# Fixing a broken BK Precision 879b LCR meter
- URL: https://ptarmiganlabs.com/fixing-a-broken-bk-precision-879b-lcr-meter/
- Published: 2015-12-06T00:35:18.000Z
- Updated: 2024-01-05T16:49:19.000Z
- Description: Once you got yourself a good multimeter, a good LCR meter is probably the next step. Remember to discharge any caps before measuring them though - otherwise the result might be what caused this post...
- Author: Göran Sander
- Tags: Electronics, #Import 2025-03-29 20:52

Some time ago I got what I thought was a score on Ebay – a really nice LCR meter at a very good price. Ok, it was broken, but the error message indicated it was just the fuse that was gone. Looked like on the right.

[According to BK’s help site](https://bkprecision.desk.com/customer/portal/articles/1535442-getting-err-02-or-fuse-message-on-lcr-meters-878b-and-879b?ref=ptarmiganlabs.com), this error could be caused by a busted fuse. It’s an SMD fuse, but not too hard to replace. Unfortunately that didn’t solve the problem… the meter was still dead after fuse replacement.

So, enter a new toy I got recently: A FLIR TG165 IR camera. Did an unboxing of it recently, it’s a very nice piece of gear. Got it from [SOS Electronic](http://www.soselectronic.com/?str=371&artnum=173704&name=flir-tg165&ref=ptarmiganlabs.com), it cost a fair bit of money, but still nothing compared to what FLIR cameras cost just a few years ago.

After replacing the fuse I powered the meter from a bench supply, and noticed a couple of things:

- Both +5V and -5V rails were showing way different values, compared to their nominal ones.
- The meter pulled more than 200 mA from the supply.

![](https://ptarmiganlabs.com/content/images/2023/01/FLIR00005.jpg)

Toasty voltage regulators!

Considering the meter normally runs off a standard 9V battery, 200 mA didn’t seem realistic. Something was wrong.. But all that energy has to go somewhere, and eventually turn into heat. So it’s just a matter of pointing the FLIR to the PCB and look for hot spots. And sure enough, two small SOT23-5 packages are way hotter than anything else on the board. The right, more prominent hotspot is a Texas Instrument TPS60400DBVT, which is a voltage inverter. Following the PCB traces from the -5V test point on the board, they ended up at that right hotspot – it was now a strong candidate for replacement.

Desoldering it was easy, it was then just a matter of powering the meter from a bench supply, providing +9V into the meter’s regular battery terminals, and -5 into the -5V test point. No problems, the meter came alive just fine.

A replacement regulator arrived a few days ago, soldering it in, re-assembling everything, adding a fresh 9V battery, and everything works great again. Win!

![](https://ptarmiganlabs.com/content/images/2023/01/FLIR00006.jpg)

No more overheating voltage regulators.

![](https://ptarmiganlabs.com/content/images/2023/01/IMG_6093_01.jpg)

This cap is way off it’s marked value..

![](https://ptarmiganlabs.com/content/images/2023/01/IMG_6094_01.jpg)

This one is spot on though.

![](https://ptarmiganlabs.com/content/images/2023/01/IMG_6095_01.jpg)

330 nF

![](https://ptarmiganlabs.com/content/images/2023/01/IMG_6081_02.jpg)

PCB of the meter, with broken chip marked.

![](https://ptarmiganlabs.com/content/images/2023/01/S20151128_005.jpg)

Broken chip, prior to removal.